Public Health Engineering Department - West Bengal

39164823 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at paikpara piped water supply scheme block_lalgola dist_murshidabad under medb phe dte. asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 125 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 22 kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 200 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check200 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 200 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 200 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 200 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 200 mm dia , thickness 5.4mm and 200 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers200x 125 mm, concentric enlarger100 x 200 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade95 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 25 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164816 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at faridpur piped water supply scheme block_bhagwangola ii dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 90 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 18.5kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 150 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check150 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 150 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 150 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 150 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 150 mm dia , thickness 5.4mm and 150 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers150x 100 mm, concentric enlarger80 x 150 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 16 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164803 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at moktarpur piped water supply scheme block_nawda dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 30 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 7.5kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers100x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 4 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164784 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at hazi mahammadpur zone i piped water supply scheme block_lalgola dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 30 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 7.5kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers100x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 4 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164768 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at nasipur piped water supply scheme block_bhagwangola ii dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 42 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 11 kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 125 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 125 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers125x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164766 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at gobindrapur piped water supply scheme block_berhampore dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 42 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 11 kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 125 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 125 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers125x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164761 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at samaskar piped water supply scheme block_berhampore dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 42 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 11 kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 125 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 125 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers125x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164726 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at gouridaspur piped water supply scheme block_lalgola dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 30 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 7.5kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers100x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 4 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164630 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at bali zone iii piped water supply scheme block_nawda dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 57 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 15 kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 150 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check150 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 150 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 150 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 150 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 150 mm dia , thickness 5.4mm and 150 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers150x 100 mm, concentric enlarger80 x 150 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 10 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

39164392 providing and installation of electro_mechanical equipment and allied works for arsenic iron removal plant at kulgachi and adjoining piped water supply scheme block_bhagwangola i dist_murshidabad under medb phe dte. part asupply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 33 m3 per hour generated head : 35 mwch q p curve of pumps in test bed has to be submitted during the delivery. 2 supply, delivery and storage at site horizontal foot mounted induction motor capacity minimum 7.5kw suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 3 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to20.5m3 / hr 4 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 5 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 6 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 8 supply, delivery and storage at site 100 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side & common header ofpump ) 10 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.compound guages ( +1 to 1 kscg ) 12 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers100x 80 mm, concentric enlarger50 x 100 mm etc. as reqd. to make the installation complete in all respect andas pernit. 13 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 15 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 16 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 17 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 18 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated copper armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 20 supply, delivery and storage at site3core 1.1 kv grade 4 sq. mm.3core xlpe insulated copper armoured cable as per technical specification of nit. ( formcc panel to motor. ) 21 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 22 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 23 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 24 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 25 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 26 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 27 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 28 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 29 supply delivery at site and storage of disinfection arrangement as per specification of nit. 30 part binstallation of all items as mentioned in sl.no.1 to 29 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 31 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1 to 29 ) as per direction and to the entire satisfaction of e.i.c. 33 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 34 operation & guarding pf pumping machinery with allied electrical installation as per direction. 35 add gst @18% 36 add cess @1%...

Public Health Engineering Department - West Bengal

38981636 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at bankar dhopadi piped water supply scheme block_ nabadwip dist. nadia under emd, phe dte. 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 29 m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate :1.8 to20.5m3 / hr 5 supply, delivery and storage at site lift type 80 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80 mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , concentric enlarger50 x 80 mm etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade25 sq.mm 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 22 supply, delivery and storage at site1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( formcc panel to motor. ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedarmoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedarmoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vaccume pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 31 supply delivery at site and storage of disinfection arrangement with flow rate 100 lph as per specification of nit. 32 part b 33 installation of all items as mentioned in sl.no.1 to 15 & 23 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981545 providing electro mechanical equipments and allied works for arsenic removal plant at dakshin jhitkapota zone i phase ii piped water supply scheme, block krishnagar i, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 95m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 150 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check125 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 125 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 125 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 125mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 150 mm dia , thickness 5.4mm and 125 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade 50 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site 1.1 kv grade 16 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 200 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures...

Public Health Engineering Department - West Bengal

38981542 providing electro mechanical equipments and allied works for arsenic removal plant at uttar tajpur phase ii piped water supply scheme, block karimpur ii, dist. nadia under emd, phe dte. 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 45 m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981290 providing electro mechanical equipments and allied works for arsenic removal plant at ghoralia zone ii phase ii piped water supply scheme, block santipur, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 28 m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate :1.8 to20.5m3 / hr 5 supply, delivery and storage at site lift type 80 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80 mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , concentric enlarger50 x 80 mm etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade25 sq.mm 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 22 supply, delivery and storage at site1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( formcc panel to motor. ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vaccume pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 31 supply delivery at site and storage of disinfection arrangement with flow rate 100 lph as per specification of nit. 32 part b 33 installation of all items as mentioned in sl.no.1 to 15 & 23 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981287 providing electro mechanical equipments and allied works for arsenic removal plant at itla phase ii piped water supply scheme, block krishnanagar i, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 57 m? per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m? / hr 5 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981279 providing electro mechanical equipments and allied works for arsenic removal plant at ghoralia zone i phase ii piped water supply scheme, block santipur, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 95m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 150 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check125 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 125 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 125 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 125mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 150 mm dia , thickness 5.4mm and 125 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site1.1 kv grade 50 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site1.1 kv grade 16 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 200 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981264 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at kulgachi phase ii piped water supply scheme, block krishnagar i, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 67m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 125 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 100 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 100 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 100mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 125 mm dia , thickness 5.4mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade 50 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site 1.1 kv grade 16 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 200 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures...

Public Health Engineering Department - West Bengal

38981258 providing electro mechanical equipments and allied works for arsenic removal plant at pansila phase ii piped water supplyscheme, block nabadwip, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 93m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 150 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check125 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 125 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 125 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 125mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 150 mm dia , thickness 5.4mm and 125 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade 50 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site1.1 kv grade 16 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 200 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981257 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at teinpur zone iv phase ii piped water supply scheme block_ karimpur ii dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 20.87 m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate :1.8 to20.5m3 / hr 5 supply, delivery and storage at site lift type 80 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80 mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , concentric enlarger50 x 80 mm etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade25 sq.mm 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 22 supply, delivery and storage at site 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( formcc panel to motor. ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedarmoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedarmoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulatedarmoured coppercable as per technical specification of nit. ( for vaccume pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 31 supply delivery at site and storage of disinfection arrangement with flow rate 100 lph as per specification of nit. 32 part b 33 installation of all items as mentioned in sl.no.1 to 15 & 23 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981192 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at sonada zone i piped water supply scheme block_ krishnanagar i dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 34 m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblock vacuum pumping machinarywith the following specification and as pernit. : a ) vacuum : upto 600 mm of hg b ) air flow rate :1.8 to20.5m3 / hr 5 supply, delivery and storage at site lift type 80 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80 mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , concentric enlarger50 x 80 mm etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to mcc panel ) 21 supply, delivery and storage at site 1.1 kv grade25 sq.mm 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for voltage stabilizer to mcc panel ) 22 supply, delivery and storage at site 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( formcc panel to motor. ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit. ( for vaccume pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply delivery at site and storage of suitable capacity power correction arrangement as per specification of nit. 31 supply delivery at site and storage of disinfection arrangement with flow rate 100 lph as per specification of nit. 32 part b 33 installation of all items as mentioned in sl.no.1 to 15 & 23 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures....

Public Health Engineering Department - West Bengal

38981181 providing electro mechanical equipments and allied works for arsenic removal plant at senpur phase ii piped water supply scheme, block krishnagar i, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. :(pumps suitable for plc operated unmaned operation facility) (for pumping water from cwr to ohr) discharge : 93m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1) with adequate margin as specified in the nit. routine test certificate of induction motor has to be submitted during delivery 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. : a) vacuum : upto 600 mm of hg b) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 150 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check125 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. (at delivery side of pump) 7 supply, delivery and storage at site 125 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve (at delivery side of pump ) 8 supply, delivery and storage at site 125 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve.(at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. (at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 125mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with ,ss internal, dn 15 gi impulse line with three way cock. 12 a) pressure guages(0 15 kg/cm2) 13 b) compound guages ( +1 to 1 kscg) 14 supply, delivery and storage at site of 150 mm dia , thickness 5.4mm and 125 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 (for suction, delivery & delivery header) along with necessarybends,fittings viz. flanges, bolts, nuts, gaskets ,eccentric reducers ,concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic/radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia,g.ipipes(medium duty),water storage pvc tank , bends,sockets, tees,fittings, and other specials,gaskets , solenoide valve ,gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. (for priming arrangement) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board (pdb)having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit.(from wbsedcl end cut out to pdb panel) ) 20 supply, delivery and storage at site 1.1 kv grade70 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit.(for pdb panel to airp mcc panel) 21 supply, delivery and storage at site1.1 kv grade 50 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. (for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site1.1 kv grade 16 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. (for mcc panel to motor) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulated armoured copper controlcable as per technical specification of nit. (formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulated armoured copper controlcable as per technical specification of nit.(for solenoid valve connection) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulated armoured coppercable as per technical specification of nit.(for vacuum pump connection) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. (earth pit 2 nos+ 2 l/a) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch ,switch board ,tube light fitting ,exhaust fan ,ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket ,fire bracket, rubber mats, shock treatment chart and first aid box,chair ,table,415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 200 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 (part a) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation (viz.pumps,valves, pipe lines etc.by two coats of epoxy paint (colour to be decided by eic) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors,valves etc. as in part a (sl no. 1to 28) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 supervision charges for electrical installation by licensed electrician as per ie rules, 1956 read with latest amendments with overhead expenditures. ...

Public Health And Engineering Department - West Bengal

37795403 providing electrical equipments for sub station at wtp under surface based pwss scheme for balagarh and pandua block in the district of hooghly. 2 supply, delivery and storage at site floor mounted, sheet steel enclosed , three panel, 12 kv, 800 a, 3 pole draw out type , scada competible vcb complete with dc power pack arrangement and all accessories as per nit specification. 3 supply, deliveryand storage at site 11 / 0.433kv, 3 phase, 2000 kva , 50 hz, dyn 11, onan, indoor type, copper wound , transformer manufactured as per is : 1180 level iiwitholtc having input voltage variation of +10% to 20% with all accessories in complicance with nit specification. 4 supply, delivery and storage at sitesheet steel enclosed, floor mounted, 415v, scada competible, power disctribution board having 2 nos 2500 a four pole extended drawout type acb as incomer, one 2500 aacb asbus coupler, 2 nos 2500 a four pole acb as outgoing feeders to pumping station, 2 nos four pole 100 a mccband 4 nos. 63 a four pole mccb for feeding different units complete with all components in compliance with nit specification. 5 supply, delivery at site and storage of 11kv ( e ) grade 3c 240sq.mm xlpe insulated aluminium conductor armoured cable conforming to is:7098 part ii from power supply agency panel board to incoming ht panel and from outgoing ht panels to transformers. 6 supply, delivery at site and storage of 415v ac, 50hz., 3 phase and neutral 2500a bus duct withelectrolytic grade aluminium flat bars in sheet steel enclosurealongwith fixing brackets and accessories from transformer secondary terminal to incomer acbs of 415v pdb incompliance with the attached technical specification. 7 supply, deliveryand storage at site 1.1kv grade xlpe insulated ar. al conductor cables of following sizes. 8 3.5c 400 sq.mm from pdb outgoing ( 2 nos ) at substationto 2 nos 2500a incomer acb of pdb cum mccpanel at clear water pump house ( 4 parallel run ) 9 3.5c 25 sq.mmfor feeding power to chlorination room with neutralisation system. 10 2c, 6sq.mm for single phase ac & dc supply & instrumentation andsupply at ht panels etc. 11 4c 16 sq.mmfor lighting, ventilation and battery charger, oltc etc. 12 supply, delivery at site and storage of 1.1kv grade multicore pvc insulated 2.5sq.mm stardard copper conductor armoured control cable. 13 supply, delivery and storage at site indoor type heat shrinkable termination kit for 3 core, 240 sqmm 11kv ( e ) grade xlpe cable. 14 supply, deliveryand storage at site safety equipment like fire extinguishers, fire buckets, rubber mats, shock treatment chart and first aid box as per satisfaction of eicas detailed in nit specification. 15 outdoor illumination of sub station in line to the technical specificationwith ldb lightings and external wiring with gi conduit etc. 16 part b ( installation part ) 17 installation of all items as mentioned in part a including supply of all erection materials, cable termination with supply of jointing kits, cable supports and clamps etc. including of ht & lt cables through permanent cable trench on gi rack / tray, earthing and lightning protection as per ie rules to the entire satisfaction of eic in compliance with the specification. ( cost includes hire charges of generator, welding set, fuels, lubricants etc. for completion of work ) 18 providing earthing and lightning protection for sub station installation as per ie rules and as per technical specification nit. 19 providing perforated hot galvanised iron cabletray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5% for laying ofht and ltcables inside the sub station on 5 m.s. channel , base plate and ms angle. 20 providing curb angle and removable chequered plate with thickness 10 mm over the open portion of the cable trench of substation after installation of the equipment in compliance with nit specification and as per direction of eic with a provision oflifting lug over the ms chequered plate. 21 high pressure testing of the substation including relevant testing of 11kv vcb switch board, cables, earthing etc. by approved agency of directorate of electricity, govt. of west bengal as per direction and to the entire satisfaction of eic. 22 commissioning of the entire installation i.e. ( 2x11 / 0.433 kv, 2000 kva ) indoor type sub station, pdb, vcb with feeding power to different work stations, cables, earthing etc. by deploying sercive engineers for final tuningas per directionand to the entire satisfaction of eic. 23 operation of the entire installation in sub station on 24 hours basis including guarding and maintenance for a period of 12 months after 3months trial run are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and word personnel from the date of commissioning. during maintenance period supply of all consumable materials, sundrys and lubricants are to be supplied. charges of electrical energyduring maintenance period will be borne by the department....

Central Public Works Department - West Bengal

36721113 tender for maintenance of horticulture work at non residential area, nizam palace, kolkata during 2022 23. sh: providing services of 01 ( one ) no. computer operator ( skilled ) and 02 ( two ) nos. un skilled personnel at o / o the deputy director ( hort. ) , khd, cpwd, nizam palace, kolkata....

Department Of Information And Cultural Affairs - West Bengal

35672791 tender notice ( 4th call ) for deployment of an agency for supply of sound system ( equipments detail will be in the e tender portal ) and 2 ( two ) qualified man power for daily sound operation of the auditorium of girish mancha for 2 years. 1 ( a ) supply of sound system ( equipments detail are given below ) and 2 ( two ) qualified man power for daily sound operation of the auditoriumof girish mancha for 1 + 1 years. only amount of service charge ( in rupees ) on total billing amount ( rs.27, 857 / ) of monthly wages, epf, esi and bonus is to be quoted 2 deployment of an agency for supply of sound system and of 2 ( two ) qualified man power having sufficient technical knowledge of concerned field , out and have 5 ( five ) years of work experience of similar nature for the term of one year. monthly minimum wages as notified / revised time to time by the labour department, govt. of west bengal will be paid. the present rate of minimum wages for zone ‘a’ vide order no.112 / stat / 3 / rw / 10 / 2022 / lcs / jlc dtd.06.07.2022 of labour deptt. is furnished below :this rate will be revised time to time as per order of labour department.each skilled rs.11180 / ( for 26 days ) [ daily :430 / ] for duty on weekly off days, double of the daily rate will be paid.both employer contribution of epf, esi and bonus will be paid asper rule. only amount of service charge ( in rupees ) on total billing amount ( rs.27, 857 / ) of monthly wages, epf, esi and bonus is to be quoted.minimum monthly wages will be revised time to time as per order of labour department, govt. of west bengal for all types of unskilled, semi skilled, skilled and highly skilled personnel. ( ii ) each personnel will get one weekly off day. engaged agency will make substitute arrangement for such weekly off day. no overtime or higher rate of wages will be paid under any circumstances. ( iii ) rate of epf ( employer’s share ) , esi ( employer’s share ) and bonus will remain unaltered unless the same is revised by the appropriate authority. ( iv ) rate of service charge [ quoted amount of service charge x 100 / rs.27, 857 / ] will remain same during the contract period with the lowest bidder. during calculation of this rate of service charge, figures arrived upto second digit after decimal will only be recknoed. ( v ) qualified personnel having sufficient technical knowledge in the respective field is to be deployed only. this department reserves the right to verify and assess the technical qualification and knowledge of any engaged personnel at any time and may instruct the agency to disengage any incapable staff. no compromise with the quality of service will be entertained under any circumstances. ( vi ) this department will review periodically the necessity of above man power, which may lead to downsizing of it in case of non essential services at that moment or may occur its reverse in case of additional requirements of any particular service in exigencies. 3 hiring of sound system equipments 4 16 channel stereo professional mixing console for music ( 1 no. ) , 12 / 16 channel professional mixing console with phantom for stage pu ( 1 no. ) , 250 watt ahuja amplifier for stage pu ( 3 no. ) , 500 watts ahuja amplifier ( 1 no. ) , 2000 watt stereo professional power amplifier ( 1 no. ) , 15 / 500 watt two way speaker box wharfedale / peavey / jbl ( original ) ( 4 nos. ) , 15 / 300 watt two way stage monitor and back speaker box ( professional quality ) ( 4 nos. ) , 12 / 150 watt hi fidelity speaker box for drama ( 14 nos. ) , 8 monitor speaker with control and amplifier for light room, green room, stage etc. ( 4 nos. ) , shure / ahuja professional dynamic microphone for music ( 8 nos. ) , shure sm58 professional dynamic microphone for music ( 2 nos. ) , shure sm57 professional dynamic microphone for music ( 2 nos. ) , hanging and boundary condenser microphone powered with drama ( 11 nos. ) , 15 band stereo graphic equalizer dod ( professional quality ) ( 2 nos. ) , digital reverb echo alesis ( professional make ) ( 1 nos. ) , microphone stands and buffer ( 10 nos. ) , voltage stabilizer, power board di connecting box ( 1 gross ) and necessary microphone cables, wiring with all allied accessories ( 1 gross ) ...

Public Health And Engineering Department - West Bengal

35494617 providing electro mechanical accessories and others for khanpur and adjoining moujas water supply scheme under bolpur mechanical division phe dte. 1.01 supply, delivery at site and storage of horizontal multi stage centrifugal pump with common base plate for pump and motor, flexible coupling, coupling guard foundation bolts etc. as per specification. pump efficiency should be greater than 65 % and rpm ( syn ) should not be more than 1500. casing ci, impeller bronze, shaft ss410 / c40, shaft sleev ss410 / ci. suction flooded type. capacity : 57.08 m³ / hr. generated head : 38 mwc. ( tc, gc & curve chart and moc issued by manufacturer are to be submitted at the time of delivery ) 1.02 supply, delivery at site and storage of horizontal foot mounted tefc squirrel cage induction motor of ie3 class suitable for above pump sets having adequate margin on bkw over the pump bkw and as per the specification. duty cycle s1, insulation class f, star delta stating. motor rating 11 kw. ( tc, gc & curve chart and moc issued by manufacturer are to be submitted at the time of delivery ) 1.03 supply, delivery at site and storage of following valves as per specification: ( tc & moc issued by manufacturer are to be submitted at the time of delivery ) 1.0301 manually operated non rising spindle ci sluice valve of pn 1.0 rating as per is:14846. 1.030101 dn 150 mm ( for pump suction line ) 1.030102 dn 125 mm ( for common header line ) 1.0302 wafer type ci butterfly valve ( wafer type three phase motorised ) confirming to is:210 , pn 1.0 rating for installation on pump delivery line. 1.030201 dn 125 mm 1.0303 cidf single door swing check non return valve as per is:5312 part 1 , pn 1.0 rating for installation on pump delivery line. 1.030301 dn 125 mm 1.0304 ci double orifice air release valve with isolation gate valve of pn 1.0 rating for installation on common header line. 1.030401 dn 50 mm 1.04 supply, delivery at site and storage of ms dismantling joint suitable for pn 1.0 rating for the following sizes for individual suction, delivery & common header of high lift clear water pump sets. 1.0401 nominal dia. : 150 mm ( suction side of pump ) 1.0402 nominal dia. : 125 mm ( delivery side & common header of pump ) 1.05 supply, delivery at site and storage of mserw pipes of dn 125 and dn150 confirming to is 1239 for fabrication of suction, delivery and common header lines in delivery section ( suitable for pn 1.0 rating ) including necessary flanges, bends, tees, bellmouths, nuts and bolts gaskets, reducers, engearger etc. as required to make the installation complete. ( tc must be submitted ) 1.06 supply, delivery at site and storage of bourdon type gauges with 150 mm dia cast aluminium dial with ss internal siphon tubes, dn 15 mm gi impulse line withthree way cock etc. 1.0601 pressure gauge ( 0 10 kg / sq.cm ) 1.0602 compound gauge ( + 1kscg to 1 kscg ) 1.07 supply, delivery at site and storage of electro magnetic flow meter with separate transmitter, 20m interconnecting cable for measuring flow of clear water. flow sensing element shall have ip68 degree of protection, flow transmitter shall be operated with 220v and shall have flow rate and flow totalizer. 1.0701 nominal dia. : 125 mm 1.08 supply, delivery and storage at site of automatically controlled diaphragm type chlorinator dosing pump with flow rate 100 lph and maximum pressure of 10 kg / cm2 with all accessories for pump & motor, foundation bolt, suction and discharge flange and with storage tank of dosing solution of 100 ltr. capacity and the prime mover to be coupled with pump of 0.5 h.p., 3 phase, 1450 rpm, squirrel cage tefc induction motor, motor will be ie3. t.c. & g.c. of pump & motor needed. 1.09 supply, delivery at site and storage of single girder construction hand operated overhead travelling crane of 2mt capacity x 4.5 m span x 4m lift x 11 m travel incorporated with triple spur gear chain pulley block, steel gantry grinder with 40 mm square rail. the bay length shall be 13 meters and to be supported on the c.c bracket. suitable size base plate and site insert plates as per manufacrurer recomendation with all accessories required for completion of the work have to be provided.all motions of the crane to be controlled from floor by hand chain. the crane shall conform to class i duty indoor operation as per is:807, is:3177 and is:3832. 1.10 supply, delivery at site and storage of 2mm thick crca sheet steel enclosed cubical type indoor floor mounted 415v power distribution board cum motor control centre having required feeders, starters etc. as per specification as follows : incommer : 160a / 36ka tpn, 415v, feeder with e / f relay mccb adjustable olr with thermo magnetic release for o / c, s / c, e / f & spd protection. all accories with digital maultifunction meter with rs485 port. outgoing ( with all protection ) : a ) 11 kw star delta feeder ( high lift ) 3nos ( 2+1 spares ) with digital maultifunction meter with rs485 port., b ) 3.7 kw dol feeder ( low lift ) 4nos ( 3+1 spares ) with digital maultifunction meter with rs485 port., c ) 1.5 kw dol feeder ( chlorination ) : 1no. with digital maultifunction meter with rs485 port., d ) 1.5 kw dol feeder ( d watering motor ) : 2nos. e ) 16 amp, tp, mcb actuator feeder 3 nos. f ) 32amp / 25ka tpn mccb feeder with timer ( outdoor lighting ) 1no, g ) 63amp / 25ka 4p mccb ( spare ) 1no. h ) 16 amp, dp, mcb feeder 1no, i ) 8 step apfc panel for improvement of power factor upto 98%, all protection & relay. panel should be compatible for trasfering data of pumps & actuators through multifuction meter with rs485 port & necessary port should be provided. each individual feeder should consist of indicator lamp ( led ) , proper rating voltmeter & ammeter. 1.11 supply, delivery at site and storage of a.c. 3 phase, 50 hz. auto / manual servo controlled oil cooled type 50 kva voltage stabilizer for unbalanced input voltage range 200 v 500 v and balanced output 415 v ac ± 1% with first filling of oil as per nit specification. t.c. & g.c. should be submitted at the time of delivery. 1.12 supply, delivery at site and storage of following materials : 1.1201 200 a re wireable type tpn main switch. 1.1202 200 a 4pole offload change over switch. 1.1203 200 a 4way copper busbar chamber box by 16swg sheet steel enclosure including porcelain chair etc. with painting complete. 1.1204 200 amps kit kat rewireable proceliain fuses carrier & base ( specification is:2086 ) . 1.13 supply, delivery at site and storage of following xlpe insulated armoured 1.1kv grade al. conductor cables. 1.1301 3.5c 50 sq.mm 1.1kv grade xlpe al. ar. cable for wbsedcl meter to main switch, main switch to bus bar chamber, bus bar to stabilizer input, stabilizer output to change over switch, change over switch to pdb incomer. 1.1302 3c 16 sq.mm 1.1kv grade xlpe al. ar. cable for pump motor to panel. 1.14 indoor and out door illumination by supplying and fitting necessary materials as follows drawing of 1c 2.5 & 1.5 sq.mm and running earth by 0.5 sq. mm 1.1kv grade pvc insulated stranded copper wire through pvc casing ( 31 points of avg. run of 15 mtrs ) , high bay led with suitable fixture, having 10 k lumen 03 nos, 1.5 mtrs led tube 6 nos, 36 w wall mounted led fixture 6 nos, 380 mm dia heavy duty five star rating exhaust fan 2 nos , 600 mm dia heavy duty five star rating pedestral fan 1 nos, 1200 mm dia anti dust energy efficient ceilling fan 3 nos, out door led with suitable fixture 6 nos, 15 a and 5 a power plug , necessary sheet steel db with suitable mcbs, piano type switches, boards, regulators etc. required to complete the job. 1.15 supply, delivery & storage at site of vertical submersible dewatering pump of discharge 10 m3 / hr. at head 10 mtr. with suitable motor . tc & gc needed. ( 1w +1s ) 1.16 supply, delivery at site and storage of earthing for lighting protection materials consisting of 50mm x 6mm main earth grid, 4nos. of 50mm dia. x 3000mm long gi pipe for earth electrode, 25mm x 3mm gi flat required length for round the roof of the pump house and required no. of proper length of gi spike as per ie rules and direction of eic for lighting protecton including earth pit chamber with cover ( 4nos. ) 1.17 supply, delivery at site and storage of safety equipment like fire extinguishers, fire buckets, rubber mats, shock treatment chart and first aid box as per satisfaction of eic and electrical inspector as well as nit specification. 1.18 supply, delivery at site and storage of gi cable tray at pump house for laying of power cable and all lt cable having proper ms structural support as per requirement as per direction of eic. 2.00 part b 2.01 low lift: supply and delivery of clear water vertical wet type submersible pump suitable for bore well conforming to is : 8034 ( and as amended there after ) with standard moc for potable clear cold water and bee 3 star rated capable of discharging noted 28.54 m³ / hr against head of 27 mtr water column. the pump shall be directly couprled with a continuous rated 2 pole suitable wet type vertical squirel cage induction motor conforming to is : 9283 ( and as amended thereafter ) , suitable for operation in ac three phases 415 v, 50hz ( category b motor ) . test certificate along with characteristic curve should be submitted at the time of delivery. 2.02 supply, delivery at site and storage of 3 core 4 sq.mm water proof flat submersible cable. 2.03 supply, delivery at site and storage of 3 core 10 sq.mm al. ar. xlpe cable for incomer for 3 nos. submersible pump. 2.04 supply, delivery and storage of following valves, pipes and gadgets etc. at site: ( a ) 80 mm dia upvc standard type column pipe ( cream colour with both side threaded and one end side socket with register kpmg ) . 2.0401 3 mtr long 2.0402 1.5 mtr long 2.0403 80 mm dia ci top and bottom adopter 2.0404 making ms fabricated sealed type top cover of 200mm / suitable dia ground tube well made of 12 mm thick ms plate with suitable hole for entry 80 mm dia column pipe and 40mm / suitable dia pipe cable protection entry and necessary drill holes on the peripheral srface of the top cover for fixing on the tubewell flanged ( supply and welding with tubewell ) and fittings of the heavy type ms pipes specials and valve properly including all joints and specials as per direction of eic. 2.0405 80mm dia. non rising spindle sluice valve ( pn 1.0 rating ) as per is14846 for wash out line, moc & tc needed for valve. 2.0406 80mm dia. n.r.v ( pn 1.0 rating ) as per is5312, moc & tc needed for valve. 2.0407 cidf 90°bend 1no., ci flanged tee 1no. blank flange 1no., ci / ms flanged short piece 0.50 mtr. 1no, ci / ms flanged pipe 1 mtr. 1 no. etc ( as per is specification and certification registered ) for construction of delivery pipe line and wash out line. 2.0408 suitable kiox box for cable connection of submersible pump motor set with degree of protection ip 65 including suitable legs and 3 nos. al. bus bar for 32 amps and all necessary earthing arrangement and insulator as per direction of eic. 2.05 making cc foundation for support of the kiosk box after excavating the earth upto a depth of 0.6 mtr below the gl including supply of all materials complete with 12 mm thick cement plastering with net cement finishing complete as per direction of eic ( size: 3 x 1 x 5 ) 2.06 supply & making necessary gi medium pipe ( dia of pipe not less than 32mm ) protection for submersible cable from kiox box to submersible pump including supply of all specials and complete the job. 2.07 laying of three cables up to 35 sq.mm in an underground trench in single tier formation ( horizontal ) the trench size : 915 mm x 760 mm average depth with brick protection on the top of each cable with 8 nos. bricks per mtr. and 4 nos. bricks per mtr. as separator between the cables including filling the space between the bricks and cables and also the trench with shifted soil, levelling up and restoring surface duly rammed. 2.08 laying of one nos. cable up to 35 sq.mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 ( eight ) nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. 2.09 making brick pillar 0.25 x 0.25 x 0.75 mtr / suitable hight for supporting of valves and pipes with 12mm thick plaster and net cement finish complete. 3.00 part c 3.01 installation of pump motor, valves and specials, gauges, electrical panels, hot cranes, including supply of all erection items, proper allingment of high lift pumping machinery, pipe support, valve support, fabrication of suction line , delivery line and common delivery header, laying of lt cables ( with necessary jointing materials, brass compensation glands ) , including saparetely earthing arrangement ( 2nos 50mm dia. x 3000mm long gi pipe for earth electrode, 25mm x 3mm gi flat required lenth for all pumping machinery, electrical installation & switches and earth pit chamber with cover ) & drawing of lighting protection arrangement etc. as required for completion of work as per relevant ie rules and hydraulic standards with the entire satisfaction of eic in compliance with nit specification including labour charges and hire charges of generator, welding set, fuel, lubricants etc. required for completion of work. 3.02 installation of voltage stabilizer & ancellaries switches and making necessary arrangement for drawing of powers including saparetely earthing arrangement ( 2nos 50mm dia. x 3000mm long gi pipe for earth electrode, 25mm x 3mm gi flat required lenth & earth pit chamber with cover ) as per ie rules along with supply of all other required materials as per direction of eic 3.03 installation of submersible pumping machinery to newly sunk tubewell along with column pipe ( as requried ) , top cover, valves, and specials of above with protection pipe, and supply of ms clamp, nut bolt, cable gland, sockets etc. making interconnection of the pump delivery line to pump collecting main line near tubewell with supply of all necessary pipe, reducer / enlarger, gi / ms specials etc. including brick, sand, cement, rod etc and laying & drawing of all cable & cable protection pipe as required and all to complete the job including all connection & testing commissioning as per direction of eic. 3.04 installation and commissioning of the above supplied chlorinator with all accessories, pvc tank and drawing of power line as per ie rules by supplying of necessary wire and continuous earthing. this include the cost of all necessary cc foundation [ at least 200mm height ] with concrete mixture [ sand, cement, stone, chips ] and neat cement finish by supplying of all required materials and testing the entire set as per direction of eic. [ power will be feed from plc panel of pumping machinery ] 3.05 installation of flow meter including supply and drawing of power and signal cables as per ie rules anolg with supply of all other required materials as per direction of eic 3.06 painting of the installation ( viz. pumps, valves, pipe lines etc. by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specification and direction of eic. 3.07 construction of rcc pit of size 2000mm x 1000mm x 750mm depth with manhole / removable cover for installation of electro magnetic flow meter with dm joint, & nrv including supply of all materials, labour, shuttering, excavation, back filling complete for clear water pumping system. 3.08 commissioning of the entire installation i.e. high lift pumps, panels etc, . as per direction and upto satisfaction of eic. 3.09 operation and maintenance of the entire installation of high lift pumping system ( clear water ) , including chlorination system on 24hours basis including guarding are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and word personnel from the date of commissioning. during maintenance period supply of all consumable materials, sundrys and lubricants are to be supplied. charges of electrical energy, chlorine gas along with its filling expenses including transportation during maintenance period will be borne by the department. for 90 days ( 3 nos operators ) 4.00 part d 4.01 supply and delivery at site of gi octagonal street light pole conical type 7 mtr. length ( top dia 70mm, bottom dia 130 mm, thick 3mm base plate 220x220x12mm, foundation bolt m20x700 with template and anchor plate, bracket single arm bracket 1500 mm long on single side with 48.3 od gi pipe.& internal junction box ( 6a, sp mcb & 4 way connector ) resin coated. 4.0101 single arm pole. 4.0102 double arm pole. 4.02 supply and delivery at site of energy efficient led smart bright street light fixture with ip66 and ik06 protected lm high pressure alluminium di cast housing with polycarbonate cover capable of delivery standard lumen output as follows .the lens plate should be bolted to the metal core pcb should not be glued . the driving current should be more than 700 ma . it should have internal surge protection of minium 4kv , lumen / watt >100, drivier efficiency > 85% , pf >0.95, thd<10%. 4.0201 philips brp409 led 110 cw m2 fg psu gr v3. / similar 4.03 supply and delivery at site of 1.1 kv grade 2 core 4 sq.mm xlpe insulated al. ar. cable conforming to is:7098 ( part i ) 1988 for outdoor lighting along with manufactures test certificate. supply of cable as per actual requirement at site. 4.04 erection of gi octagonal pole of length of 7 meter in rcc ( 1:2:4 ) foundation of 400x400mm of depth of 1300 mm below gl and 200 mm just above gl. 4 nos j type foundation bolt of 20 mm dia and 600 mm long grouted into rcc foundation as per base plate of pole.projected length of 100 mm also considered for fitting with the base plate of the pole.there should be a provision of two number flexible pvc pipe of 63mm dia for cable entry as per supplied drawing.also the foundation along material will be made as per departmental drawing and design. 4.05 laying of one no. cable up to 35 sq.mm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 ( eight ) nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. 4.06 fitting fixing above supplied led light fitting complete with all accessories to be fixed with s&f length of 1.5 sqmm pvc insulated single core stranded annealed copper wire and making connections as required complete. 4.07 earthing with 1no. of g.i. earth spike ( 20 mm dia. x 1.5 mtr. long ) driven into the ground upto 2 mtr.. drawing earth line with separate 6 swg g.i. wires providing 15 mm dia. g.i. pipe protection from earth spike feeder box / junction box / poles and fixing to the same by suitable nuts & bolts all complete as per direction of eic. 4.08 supply & delivery of plastic chair without arm. 4.09 supply & delivery of plastic table....

Public Health Engineering Department - West Bengal

35423770 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at maniknagar piped water supplyscheme, block shantipur, dist. nadia under emd, phe dte. 2.00 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as per nit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 31 m3 per hour generated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3.00 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. 4.00 supply, delivery and storage at site of monoblockvvacuum pumping machinary with the following specification and as per nit. : a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5.00 supply, delivery and storage at site lift type 80 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6.00 supply, delivery and storage at site of ci doble flanged single door swing check 80 mm dia n.r.v as per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7.00 supply, delivery and storage at site 80 mm dia cast iron actuator operated wafer type butterfly valve generally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8.00 supply, delivery and storage at site 80 mm dia double flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9.00 supply, delivery and storage at site 80 mm dia cast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10.00 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header of pump ) 11.00 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 11.10 a ) pressure guages ( 0 15 kg / cm2 ) 11.20 b ) compound guages ( +1 to 1 kscg ) 12.00 supply, delivery and storage at site of 80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessary bends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect and as per nit. 13.00 supply delivery and storage at site of ultrasonic / radar type continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 14.00 supply, delivery and storage at site 20 mm dia, g.i pipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pump complete in all respect as per nit. ( for priming arrangement ) 15.00 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted 415 volt mcc panel having required feeders with plc as per specification given in nit. 16.00 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted 415 volt power distribution board ( pdb ) having required feeders as per specification given in nit. 17.00 supply, delivery and storage at site 1.1 kv grade 35 mm2 3½ core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 18.00 supply, delivery and storage at site 1.1 kv grade 50 mm2 3½ core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 19.00 supply, delivery and storage at site 3.5 core 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 20.00 supply, delivery and storage at site 3 core 1.1 kv grade 6 sq. mm. 3 core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 21.00 supply, delivery and storage at site 1.1 kv grade 2.5 sq. mm. 12 core pvc insulated copper control cable as per technical specification of nit. ( for mcc panel to actuator. ) 22.00 supply, delivery and storage at site 1.1 kv grade 2.5 sq. mm. 2 core pvc insulated copper control cable as per technical specification of nit. ( for solenoid valve connection ) 23.00 supply, delivery and storage at site 1.1 kv grade 4 sq. mm. 2 core pvc insulated copper cable as per technical specification of nit. ( for vacuum pump connection ) 24.00 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos + 2 l / a ) 25.00 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panel having proper m.s. structural support as per nit specification and direction of eic. 26.00 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixture complete as per specification of nit. 27.00 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table , 415 volt danger board complete as per specification of nit. 28.00 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 29.00 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 29.10 part b 30.00 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost of welding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage water as per hydraulic standard & ie rules in compliance with specification of nit and upto entire satisfaction of eic. 31.00 painting of the installation ( viz. pumps, valves, pipe lines etc. by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 32.00 testing & commissioning of the entire installation i.e. pumps, motors, valves etc. as in part a ( sl no. 1 to 28 ) as per direction and to the entire satisfaction of e.i.c. 33.00 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department....

Public Health Engineering Department - West Bengal

35228406 supply, delivery, installation and trial operation of electro mechanical components and allied works at ground water based tubewell no i , ii and arsenic iron removal plant at mabarakpur piped water supply scheme in the district of malda 3 submersible pump directly coupled with water proof suitable size motor having following specification:pumpshaft stainless steelimpeller s.s / gmoutlet size 65 mmmotorsubmersible type 3 phase, 50 hz, 415v ± 10% , 2900 rpmmotor mustbe suitable for operation with star delta starter this item will be procured based on yield test report of t / w and best efiiciency point as per direction of eic. test certificate along with characteristic curve shoule besubmitted at the time of delivery. 4 for t / w no. i & iidischarge of clear water = ( q ) = 33 m3 / hr.total head ( h ) = 35 m. 5 1.1 kv grade 2.5 sqmm 3 core water proofflat submersible cable for above motor. 6 1.1 kv grade 16 sqmm 4 core xlpe insulated al. ar. cable cable conforming to is 7098 ( part 1 ) 1988 with upto date amendment. 7 supply, delivery and storage at site of wall mounted 2 mm. thick epoxy painted sheet steel enclosed front open fully panel for fully automatic cum manual control centre for operation of the pump motor in dol mode, actuator with dol starter, chlorinator with dol starter and timer operated outdoor and indoor lighting and also spares feeder as per approved drawingand nit specification. 8 for t / w no. i & iirange of pmcc panel:5 hp to 7.5 hp dol 9 supply and delivery of the following valves, pipes, gauges etc. at site of t / w no. i & ii. 10 80 mm dia m.s. seamless column pipe ( black ) 6.8 mm to 7.1 mm thick with 150 mm long heavy type socket at one end. 11 3.00 mtr. long excluding socket having 8 t.p.i. thread. 12 1.5 mtr. long excluding socket one end having a thread of 11 t.p.i. & the other end having a thread of 8 t.p.i. 13 heavy type suitabledia ms suspension clamp along with nuts bolts and washer. 14 cast iron wafer type three phase actuator ( rotork range, three phase 415 v, multiturn electrically actuated ) operated butterfly valve of dia 80mm ( p.n 1.0 ) as per ( is 13095 ip 68 ) test certificates from both the manufacturer are to be submitted at the time of delivery 15 80mm dia cidf sluice valve 1 no., non return valve 1 no., cidf 90° bend 1no., ci flanged tee 1no. blank flange 1no., ci / ms flanged short piece 0.50 mtr. 2 nos, ci / ms flanged pipe 1 mtr. 2 nos. etc as per is specification and certification for construction of delivery pipe line and wash out line. 16 heavy type 250 mm dia split type tube well cover with 12 mm thick clamping arrangement including holes of column pipe, air pipe and cable entry with 2 sets heavy type suspension clump, nuts, bolts and washer as per departmental design. 17 depth gauge 100mm dia with steel air pipe of required length with all accessories for the above work including supply of good quality hand pump. ( this cost includes 15 mm. dia g.i. pipes and specials ) 18 pressure gauge ( h.guru / febig ) 150mm dia ( 0 7kg / sq.cm ) brass cock and fitting complete. ( this cost includes 15 mm. dia g.i. pipes and specials ) 19 50 mm. dia. non metalic pipes ( is:14930 ) and specials for protection of submersible cable ( as per site requirement ) 20 anti snapping safety device for pump set by supplying suitable size ms clamps two sets and nylon rope of required length including supplying of nuts, bolts and all other materials. 21 100 amps porcelin based rewireable type male female kit kat fuse unit 22 100 amp 415 v rewireable type tpn main switch. 23 laying of 16 sq. mm. 4 core al. ar. cable in wall / floor by supplying of all necessary materials as per ie rules and as per direction 24 installation of the materials ( to be supplied under above sl no 1 to 3.01 & 5 to 6.13 ) such as pump motor set with column pipes, valves, panel, fiting fixing pressure gauge, depth gauge, non return valve & drawing delivery out let & washout line with the supplied specials / accessories by providing antisnapping cage of suitable size including supply of cable gland, sockets, wooden board, control cable etc including brick, sand, cement rod etc as required to complete the job as per direction and up to the entire satisfaction of the eic. 25 making brick pillar 0.25 mtr x 0.25 mtr. for supporting of valves and pipes with 12 mm thick plaster and net cement finish complete. 26 supply, delivery of m.s kiosk box of 661mm x 559 mm ( lxw ) size having thickness of 1.5 mm with angle support at four legs having hight of 661 mm with provision of locking arrangement, supply of lock, cable entry point incl painting by one coat of black paint over one coat of primer all complete. 27 making suitable size pump foundation including erection of kiosk box with supplying of necessary cement, sand and stone chips including plastering and net cement finish complete. 28 making double earthing arrangement in compliance with ie rules by g.i. pipe electrode of 50 mm. dia 3 mtr. long 2 nos for panel and pumping machinery 25 mm. x 6 mm. g.i. earth strips from earth pit to panel and all other accessories required to complete the work. 29 making internal electrification of pump house consisting of two bracket point, one tube light point, two bulk head point, one fan point and 1 no. 74 watt led fixture with arm bracket at outside and one three pin plug point including supply of all necessary materials to complete the work as per ie rules and as per direction ( all the fittings and lamp should be led type as per choice of eic ) 30 supply and delivery at site 3 phase oil cooledtype servo motor operated copper wound line voltage corrector conforming to is 9815 ( pt. 1 ) 1994 suitable for un balanced input voltage phase to phase 200v. 500v including first filling oil as per is 335 where applicable as per approved drawingand nit specification. 31 for t / w no. ii15 kva 32 100 amp 4 pole on load change over switch 33 100 amp re wireable type tpn main switch 34 100 amp 4 way cu basbar chamber box by 16 swg sheet steel enclosure including porcelain chair etc.with painting as per direction of e.i.c. 35 1.1 kv grade 415 v, 16 sqmm, 4 core pvc insulated aluminiumarmoured cable. 36 making brick built foundation with supplying of all required materials suitable for the above voltage stabilizer by ( 4:1 ) cement mortar including holding down foundation bolts and 12 mm thick plaster with neat cement finish, sloping all complete as per direction of eic. 37 fitting , fixing of change over switch, busbar chamber and main switch as mentioned in item no. 17.02, 17.03 and 17.04 on the iron angle frame of suitable size fixed at suitable position on wall by supplying all necessary fixing materials all complete as per direction of eic. 38 installation of the above voltage stabilizer as in item no.17.01 on the foundation including making all connection complete as per direction. 39 drawing and connection of cable as in item no. 17.05 on wall / surface from change over to panel via voltage stabilizer, bus bar and main switch incl. s & fitting fixing of required nos. of ms saddles with earthing attachment in 10 swg gi ( hot dip ) wire, making holes etc. as necy. mending good damages and painting. 40 making joints of the cable by supplying compresion type gland thimple, socket etc. as per requirement and as per direction of eic. 41 double earthing the whole installations complying with ir rules including supplying of all necessary earthing materilas for voltage corrector device to complete the job as per direction of eic. 42 supply & delivery of automatically controlled 0 100 lph diaphargm type chlorinator for accurate dosing of chlorine solution into the waterby connecting metering pump ( diaphragm type ) having specification as per nit: ( including making provision for inlet line to the actual storage tank of dosing solution of all materials. ) [ test & warrantycertificatesare to be submitted at the time of delivery ] 43 installation of above supplied chlorinator including supplying of suitable capacity main switch ( havells ) starter & drawing of power line by supplying pvccopper wire & continuous earthing. this include the cost of all necessary foundation ( at least 200mm height ) with concrete mixture ( sand, cement, stone ) and neat cement finish by supplying of all required materials and testing the entire set by supplying necessary chemical for at least 04 ( four ) hourstrial runas perentire satisfaction of the eic. 44 supply and delivery at site of calcium hypochlorite granules minimum cl content 60% 65% in air tight plastic jar ( 25 kg each ) as per direction of e.i.c. ( make phe approved ) . 45 supply & delivery ofmoulded chair. 46 supply & delivery of the moulded table. 47 supply, delivery & installation of the following fan as directed by eic. a ) ceiling fan 1200mm sweep or b ) wall mounting fan 400 mm sweep including fan clamp as and when required. 48 commissioning of the installation with full satisfaction of eic and trial run as per departmental operation & guarding by engaging skilled staff for 3 months. ( tw no ii ) 49 part b:arsenic iron removal plant 50 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification : ( pumps suitable for plc operated unmaned operation facility and pumping water from cwr to ohr ) discharge : 70 m3 per hour generated head : 40 mwcthis item will be procured based on yield test report of t / w and best efiiciency point as per direction of eic.h q p curve of pumps in test bed has to be submitted during the delivery. 51 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above in item no. 32.00 with adequate margin conforming to ie 3 energy efficient, 1440 rpm, ac, 3 phase, 50 hz. + / 5%, 415 v + / 10%, class f insulation with temperature rise limit to class b insulation, ambient temperature 50 degree centrigade, ip 55, s1 duty as per technical specification.routine test certificate of induction motor has to be submitted during delivery 52 supply, delivery and storage at site of monoblock vacuumpumping machinary with the following specification and as pernit. :a ) vacuum : upto 600 mm of hgb ) air flow rate :1.8 to 20.5 m3 / hr 53 supply, delivery and storage at site lift type 150 mm footvalve combined with stainer as per is : 4038 pn 1.6 and asper detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 54 supply, delivery and storage at site 150 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.: n.b. : test certificate to be produced for each valve. ( at suction side of pump ) 55 supply, delivery and storage at site of ci doble flanged single door swing check100 mm dia n.r.vas per is : 5312, part i, pn 1.0. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 56 cast iron wafer type three phase actuator ( rotork range, three phase 415 v, multiturn electrically actuated ) operated butterfly valve of dia 100 mm ( p.n 1.0 ) as per ( is 13095 ip 68 ) test certificates from both the manufacturer are to be submitted at the time of delivery ( at delivery side of pump ) 57 supply, delivery and storage at site 150 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.: n.b. : test certificate to be produced for each valve. ( at common delivery header ) 58 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 59 supply, delivery and storage at site ms dismantling joint dn 100 mm pn 1.0 ( for delivery side ofpump ) 60 supply, delivery and storage at site ms dismantling joint dn 150 mm pn 1.0 ( for common header ofpump ) 61 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock.pressure guages ( 0 15 kg / cm2 ) 62 supply, delivery and storage at site of150 mm dia , thickness 5.4 mm and 100 mm dia 5.4 mm thick ms black pipe conforming to is:1239 part 1 ( 2004 ) ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , 150 mm x 100 mm ecentric reducer, concentric enlarger80x100 mm etc. as reqd. to make the installation complete in all respect. 63 supply, delivery and storage at site 20 mm dia, g.i pipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pump complete in all respect as per nit. ( for priming arrangement ) 64 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc. incomer ( 250 a ) 1 no, outgoing feeder ( 25 35 hp, s d ) 2 nos, , valve actuator starter 3 nos, cholrinator starter ( 0.5 hp, dol ) 1 no, vacuum pump starter ( 1 hp, dol ) 1 no, blower starter ( 7.5 hp, dol ) , outdoor lighting feeder and control feeder and genearl feeder and plc feeder. 65 200 amps, 415 v porcelin based rewireable type male female kit kat fuse unit with extension strip 66 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated al. armoured cable 67 supply, delivery and storage at site 1.1 kv grade 6 mm23core xlpe insulated copper cable. ( frommcc panel to motor. ) 68 supply, delivery and storage at site 1.1 kv grade25 mm2 4 core xlpe insulated aluminiun armoured cable. ( from arp pump house to tube well site ) 69 supply, delivery and storage at site 1.1 kv grade6 mm2 3core xlpe insulated al. armoured cable ( from mcc panel to actuator for power ) 70 supply, delivery and storage at site1.1 kv grade 1.5 sq. mm.12core pvc insulatedcopper controlcable ( from mcc panel to actuator for control ) 71 supply, delivery and storage at site of electromagnetic type flowmeter with separate transmitter with suitable length interconnecting cable for measuring flow of clear water. flow sensing element shall have ip 68 degree of protection. flow meter shall be opearted at 220 v and shall have flow rate and flow totalisation ( dn 150 mm ) 72 providing earthing & lightning protection for pump house and electrical installation as per iss and ie rules. ( earth pit 2 nos+ 2 l / a ) 73 supply and fixing of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panel, motor and other electrical accessories having proper m.s. structural support as per direction of eic. 74 supply delivery at site and storage of indoor and oudoor illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per nit specification. 75 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete. 76 supply, delivery and installation of automatically controlled 0 100 lph diaphargm type chlorinator for accurate dosing of chlorine solution into the waterby connecting metering pump ( diaphragm type ) as per nit specification. 77 supply delivery and installation storage of 50 kva power correction arrangement as per nit specification. 78 installation of all items as mentioned in sl.no.32 to 53 including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage water as per hydraulic standard & ie rules in compliance upto entire satisfaction of eic. 79 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per direction of eic. 80 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in sl no. 32 to 53 as per direction and to the entire satisfaction of e.i.c. 81 operation and maintenance of the entire installation in high lift and low lift pumping stations on 16 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be born by the department. ( for tw no. i and airp site ) 82 n.b. progressive bills shall only be done after third party inspection agency engaged by phed....

Public Works Department - West Bengal

35221931 bids are invited for manpower data center writers building pwd deployment of data centre and network support skilled personnel level 1 total quantity : 216...

Department Of Information And Cultural Affairs - West Bengal

34796220 work related to deployment of an agency for supply of sound system ( 3rd call ) ( equipments detail will be in the e tender portal ) and 2 ( two ) qualified man power for daily sound operation of the auditorium of girish mancha for 1 + 1 years 1 ( a ) supply of sound system ( equipments detail are given below ) and 2 ( two ) qualified man power for daily sound operation of the auditoriumof girish mancha for 1 + 1 years. only amount of service charge ( in rupees ) on total billing amount ( rs.27, 857 / ) of monthly wages, epf, esi and bonus is to be quoted 2 deployment of an agency for supply of sound system and of 2 ( two ) qualified man power having sufficient technical knowledge of concerned field , out and have 5 ( five ) years of work experience of similar nature for the term of one year. monthly minimum wages as notified / revised time to time by the labour department, govt. of west bengal will be paid. the present rate of minimum wages for zone ‘a’ vide order no.112 / stat / 3 / rw / 10 / 2022 / lcs / jlc dtd.06.07.2022 of labour deptt. is furnished below :this rate will be revised time to time as per order of labour department.each skilled rs.11180 / ( for 26 days ) [ daily :430 / ] for duty on weekly off days, double of the daily rate will be paid.both employer contribution of epf, esi and bonus will be paid asper rule. only amount of service charge ( in rupees ) on total billing amount ( rs.27, 857 / ) of monthly wages, epf, esi and bonus is to be quoted.minimum monthly wages will be revised time to time as per order of labour department, govt. of west bengal for all types of unskilled, semi skilled, skilled and highly skilled personnel. ( ii ) each personnel will get one weekly off day. engaged agency will make substitute arrangement for such weekly off day. no overtime or higher rate of wages will be paid under any circumstances. ( iii ) rate of epf ( employer’s share ) , esi ( employer’s share ) and bonus will remain unaltered unless the same is revised by the appropriate authority. ( iv ) rate of service charge [ quoted amount of service charge x 100 / rs.27, 857 / ] will remain same during the contract period with the lowest bidder. during calculation of this rate of service charge, figures arrived upto second digit after decimal will only be recknoed. ( v ) qualified personnel having sufficient technical knowledge in the respective field is to be deployed only. this department reserves the right to verify and assess the technical qualification and knowledge of any engaged personnel at any time and may instruct the agency to disengage any incapable staff. no compromise with the quality of service will be entertained under any circumstances. ( vi ) this department will review periodically the necessity of above man power, which may lead to downsizing of it in case of non essential services at that moment or may occur its reverse in case of additional requirements of any particular service in exigencies. 3 hiring of sound system equipments 4 16 channel stereo professional mixing console for music ( 1 no. ) , 12 / 16 channel professional mixing console with phantom for stage pu ( 1 no. ) , 250 watt ahuja amplifier for stage pu ( 3 no. ) , 500 watts ahuja amplifier ( 1 no. ) , 2000 watt stereo professional power amplifier ( 1 no. ) , 15 / 500 watt two way speaker box wharfedale / peavey / jbl ( original ) ( 4 nos. ) , 15 / 300 watt two way stage monitor and back speaker box ( professional quality ) ( 4 nos. ) , 12 / 150 watt hi fidelity speaker box for drama ( 14 nos. ) , 8 monitor speaker with control and amplifier for light room, green room, stage etc. ( 4 nos. ) , shure / ahuja professional dynamic microphone for music ( 8 nos. ) , shure sm58 professional dynamic microphone for music ( 2 nos. ) , shure sm57 professional dynamic microphone for music ( 2 nos. ) , hanging and boundary condenser microphone powered with drama ( 11 nos. ) , 15 band stereo graphic equalizer dod ( professional quality ) ( 2 nos. ) , digital reverb echo alesis ( professional make ) ( 1 nos. ) , microphone stands and buffer ( 10 nos. ) , voltage stabilizer, power board di connecting box ( 1 gross ) and necessary microphone cables, wiring with all allied accessories ( 1 gross ) ...

Public Health Engineering Department - West Bengal

34321531 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at khaspu piped water supplyscheme, block tehatta i, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 32 m3 per hourgenerated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site3.5core 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department....

Public Health Engineering Department - West Bengal

34321471 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at jitpur piped water supplyscheme, block tehatta i, dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 32 m3 per hourgenerated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of 100 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site3.5core 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department....

Department Of Information And Cultural Affairs - West Bengal

34060939 work related to deployment of an agency for supply of sound system ( equipments detail will be in the e tender portal ) and 2 ( two ) qualified man power for daily sound operation of the auditorium of girish mancha for 1 + 1 years 1 ( a ) supply of sound system ( equipments detail are given below ) and 2 ( two ) qualified man power for daily sound operation of the auditoriumof girish mancha for 1 + 1 years. only amount of service charge ( in rupees ) on total billing amount ( rs.27, 857 / ) of monthly wages, epf, esi and bonus is to be quoted 2 deployment of an agency for supply of sound system and of 2 ( two ) qualified man power having sufficient technical knowledge of concerned field , out and have 5 ( five ) years of work experience of similar nature for the term of one year. monthly minimum wages as notified / revised time to time by the labour department, govt. of west bengal will be paid. the present rate of minimum wages for zone ‘a’ vide order no.112 / stat / 3 / rw / 10 / 2022 / lcs / jlc dtd.06.07.2022 of labour deptt. is furnished below :this rate will be revised time to time as per order of labour department.each skilled rs.11180 / ( for 26 days ) [ daily :430 / ] for duty on weekly off days, double of the daily rate will be paid.both employer contribution of epf, esi and bonus will be paid asper rule. only amount of service charge ( in rupees ) on total billing amount ( rs.27, 857 / ) of monthly wages, epf, esi and bonus is to be quoted.minimum monthly wages will be revised time to time as per order of labour department, govt. of west bengal for all types of unskilled, semi skilled, skilled and highly skilled personnel. ( ii ) each personnel will get one weekly off day. engaged agency will make substitute arrangement for such weekly off day. no overtime or higher rate of wages will be paid under any circumstances. ( iii ) rate of epf ( employer’s share ) , esi ( employer’s share ) and bonus will remain unaltered unless the same is revised by the appropriate authority. ( iv ) rate of service charge [ quoted amount of service charge x 100 / rs.27, 857 / ] will remain same during the contract period with the lowest bidder. during calculation of this rate of service charge, figures arrived upto second digit after decimal will only be recknoed. ( v ) qualified personnel having sufficient technical knowledge in the respective field is to be deployed only. this department reserves the right to verify and assess the technical qualification and knowledge of any engaged personnel at any time and may instruct the agency to disengage any incapable staff. no compromise with the quality of service will be entertained under any circumstances. ( vi ) this department will review periodically the necessity of above man power, which may lead to downsizing of it in case of non essential services at that moment or may occur its reverse in case of additional requirements of any particular service in exigencies. 3 hiring of sound system equipments 4 16 channel stereo professional mixing console for music ( 1 no. ) , 12 / 16 channel professional mixing console with phantom for stage pu ( 1 no. ) , 250 watt ahuja amplifier for stage pu ( 3 no. ) , 500 watts ahuja amplifier ( 1 no. ) , 2000 watt stereo professional power amplifier ( 1 no. ) , 15 / 500 watt two way speaker box wharfedale / peavey / jbl ( original ) ( 4 nos. ) , 15 / 300 watt two way stage monitor and back speaker box ( professional quality ) ( 4 nos. ) , 12 / 150 watt hi fidelity speaker box for drama ( 14 nos. ) , 8 monitor speaker with control and amplifier for light room, green room, stage etc. ( 4 nos. ) , shure / ahuja professional dynamic microphone for music ( 8 nos. ) , shure sm58 professional dynamic microphone for music ( 2 nos. ) , shure sm57 professional dynamic microphone for music ( 2 nos. ) , hanging and boundary condenser microphone powered with drama ( 11 nos. ) , 15 band stereo graphic equalizer dod ( professional quality ) ( 2 nos. ) , digital reverb echo alesis ( professional make ) ( 1 nos. ) , microphone stands and buffer ( 10 nos. ) , voltage stabilizer, power board di connecting box ( 1 gross ) and necessary microphone cables, wiring with all allied accessories ( 1 gross ) 5 government taxes 6 all applicable government taxes...

Public Health Engineering Department - West Bengal

33964087 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at karuigachi piped water supply scheme, block dist. nadia under emd, phe dte 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 36 m3 per hourgenerated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site3.5core 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 total of part a 38 total of part b 39 total 40 add: gst @ 18% 41 total 42 add: lw cess @ 1%...

Public Health Engineering Department - West Bengal

33964079 providing and installation of electro mechanical equipments and allied works for arsenic removal plant at madhupur piped water supply scheme, block dist. nadia under emd, phe dte. 2 supply, delivery and storage at site of horizontal split casing centrifugal pumping machineries with baseplate, flexible coupling, coupling guard, foundation bolt etc. having the following specification and as pernit. : ( pumps suitable for plc operated unmaned operation facility ) ( for pumping water from cwr to ohr ) discharge : 33 m3 per hourgenerated head : 40 mwc h q p curve of pumps in test bed has to be submitted during the delivery. 3 supply, delivery and storage at site horizontal foot mounted induction motor suitable for the pump duty mentioned above ( item no 1 ) with adequate margin as specified in the nit. 4 supply, delivery and storage at site of monoblockvvacuum pumping machinarywith the following specification and as pernit. :a ) vacuum : upto 600 mm of hg b ) air flow rate : 1.8 to 20.5 m3 / hr 5 supply, delivery and storage at site lift type 100 mm foot valve combined with stainer as per is : 4038 pn 0.6 and as per detail given in the nit . : n.b. : test certificate to be produced for each valve ( at suction side of pump ) 6 supply, delivery and storage at site of ci doble flanged single door swing check80 mm dia n.r.vas per is : 5312, part i, pn 1.0 and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at delivery side of pump ) 7 supply, delivery and storage at site 80 mm diacast iron actuator operated wafer type butterfly valvegenerally conforming to is:13095 and pn 1.0. and as per detail given in nit. : n.b. : test certificate to be produced for each valve ( at delivery side of pump ) 8 supply, delivery and storage at site 80 mm diadouble flanged cast iron manually operated non rising spindle sluice valve generally conforming tois:14846 pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 9 supply, delivery and storage at site 80 mm diacast iron kinetic double orifice air released valve as per relevant is, pn 1.0.and as per detail given in nit. : n.b. : test certificate to be produced for each valve. ( at common delivery header ) 10 supply, delivery and storage at site ms dismantling joint dn 80mm pn 1.0 ( for delivery side & common header ofpump ) 11 supply, delivery and storage at site bourdon type pressure & compound gauges, 150 mm dia cast aluminium dial with , ss internal, dn 15 gi impulse line with three way cock. 12 a ) pressure guages ( 0 15 kg / cm2 ) 13 b ) compound guages ( +1 to 1 kscg ) 14 supply, delivery and storage at site of80 mm dia , thickness 5.4mm and 80 mm dia 5.4 mm thick ms black pipe conforming to is:3589 gr.330 ( for suction, delivery & delivery header ) along with necessarybends, fittings viz. flanges, bolts, nuts, gaskets , eccentric reducers , concentric enlarger etc. as reqd. to make the installation complete in all respect andas pernit. 15 supply delivery and storage at site of ultrasonic / radartype continuous level measuring unit with provision of 4 to 20 ma analogue signal, indicator and recorder for continuous level monitoring as well as 5 nos. relay out put for sensing high, low, low low level in suction sump as per specification given in nit. 16 supply, delivery and storage at site20 mm dia, g.ipipes ( medium duty ) , water storage pvc tank , bends, sockets, tees, fittings, and other specials, gaskets , solenoide valve , gate valve for auto & manual operation etc. as reqd. to make the piping arrangement of vacuum pumpcomplete in all respect as pernit. ( for priming arrangement ) 17 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor floor mounted415 volt mccpanelhaving required feeders with plc as per specification given in nit. 18 supply, delivery and storage at site 2 mm. thick crca sheet steel enclosed cubical type indoor wall mounted415 volt power distribution board ( pdb ) having required feedersas per specification given in nit. 19 supply, delivery and storage at site 1.1 kv grade35 mm2 3½core xlpe insulated cupper armoured cable as per technical specification of nit. ( from wbsedcl end cut out to pdb panel ) ) 20 supply, delivery and storage at site 1.1 kv grade50 mm2 3½core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb panel to airp mcc panel ) 21 supply, delivery and storage at site3.5core 1.1 kv grade 25 sq. mm. xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for pdb to low lift mcc panel . ) 22 supply, delivery and storage at site3core 1.1 kv grade 6 sq. mm.3core xlpe insulated aluminiun armoured cable as per technical specification of nit. ( for mcc panel to motor ) 23 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.12core pvc insulatedcopper controlcable as per technical specification of nit. ( formcc panel to actuator. ) 24 supply, delivery and storage at site1.1 kv grade 2.5 sq. mm.2core pvc insulatedcopper controlcable as per technical specification of nit. ( for solenoid valve connection ) 25 supply, delivery and storage at site1.1 kv grade 4 sq. mm.2core pvc insulatedcoppercable as per technical specification of nit. ( for vacuum pump connection ) 26 earthing & lightning protection for pump house and electrical installation as per iss and ie rules and as per technical specification of nit. ( earth pit 2 nos+ 2 l / a ) 27 supply, delivery at site and storeage of gi perforated cable tray at pump house for laying of incoming & outgoing power and control cables to and from mcc panelhaving proper m.s. structural support as per nit specification and direction of eic. 28 supply delivery at site and storage of illumination arrangement like suitable size wire, switch , switch board , tube light fitting , exhaust fan , ceilling fan , led outdoor fixturecomplete as per specification of nit. 29 supply delivery at site and storage of safety equipment like suitable capacity fire extinguisher , sand bucket , fire bracket, rubber mats, shock treatment chart and first aid box, chair , table, 415 volt danger board complete as per specification of nit. 30 supply and delivery at site and storage of suitable capacity power corection arrangement as per specification of niet 31 supply and delivery at site and storage of suitable capacity disinfection arrangement with flow rate 100 lph as per specification of niet 32 part b 33 installation of all items as mentioned in sl.no.1 to 28 ( part a ) including construction of pump foundations, pipe supports, valve supports, laying of cables with necessary jointing materials, earthing arrangement of motors, starters, including supply of all erection items viz. rubber gaskets, nuts & bolts etc., including cost ofwelding etc. as required for complete installation including making slope of floor and arrangement of removing gland leckage wateras per hydraulic standard & ie rules in compliance with specification of nitand upto entire satisfaction of eic. 34 painting of the installation ( viz.pumps, valves, pipe lines etc.by two coats of epoxy paint ( colour to be decided by eic ) over a coat of primer as per nit specifiaction & direction of eic. 35 testing & commissioning of the entire installation i.e.pumps, motors, valves etc. as in part a ( sl no. 1to 28 ) as per direction and to the entire satisfaction of e.i.c. 36 operation and maintenance of the entire installation in high lift pumping stations on 24 hrs. basis including guarding for a period of 90 days are to be provided with supply of skilled, semi skilled and un skilled personnel including watch and ward personnel from the date of commissioning. during maintenance period supply of all consumable materials sundrys and lubricants are to be supplied. charges of electrical energy during maintenance period will be borne by the department. 37 total of part a 38 total of part b 39 total 40 add: gst @ 18% 41 total 42 add: lw cess @ 1%...

Central Public Works Department - West Bengal

33048284 maintenance of horticulture work at non residential area, nizam palace, kolkata during 2022 23. sh: providing services 02 ( two ) nos. un skilled personnel at o / o the deputy director ( hort. ) , khd, kolkata....

The Bhagirathi Cooperative Milk Producers Union Limited - West Bengal

32181957 engagement of agency / contractor towards supply of skilled, semi skilled and un skilled personnel 1 daily commission / service charges for supply of personnel 2 un skilled personnel 3 semi skilled personnel 4 skilled personnel sr. assistant 5 skilled personnel sales executive 6 skilled personnel deo / assistant 7 skilled personnel driver / jr. assistant / supervisor...

Central Public Works Department - West Bengal

29377323 maintenance of horticulture work at non residential area, nizam palace, kolkata during 2021 22. sh: providing services of 01 no. semi skilled personnel at o / o the deputy director hort., khd, kolkata....

Central Public Works Department - West Bengal

29321854 maintenance of horticulture work at non residential area, nizam palace, kolkata during 2021 22. sh: providing services of 01 no. semi skilled personnel under director hort., o / o the sdg prk, cpwd, kolkata....

Central Public Works Department - West Bengal

29208082 maintenance of horticulture work at non residential area, nizam palace kolkata during 2021 22. sh: providing services of 02 nos semi skilled personnel at o / o the deputy director hort., khd, kolkata....

Central Public Works Department - West Bengal

27291090 maintenance of horticulture work at non residential area, nizam palace, kolkata during 2020 21. sh providing services of 01 no. semi skilled personnel at o/o the director hort. and 02 nos. semi skilled personnel at o/o the deputy director hort., khd, kolkata....

West Bengal State University - West Bengal

26080320 electro mechanical operation , maintenance and monitoring of 33/0 . 433 kva sub station , operation of pumps and motors and diesel generators ( 02 nos . ) works under wbsu for a period of one ( 01 ) calendar year ( in three shifts basis per each day ) , electro mechinical operation , maintenance and monitoring of 33/0 . 433 kva sub station , operation of pumps and motors and diesel generators ( 02 nos . ) under wbsu for a period of one ( 01 ) calendar year ( in three shifts basis per each day ) ( re tender ) . rates to be quoted for 12 calender months only . the work to be executed in three ( 03 ) working shifts per day . each shift to involve 01 skilled personnel + 01 unskilled personnel , shift 1 ( 1 skilled + 1 unskilled personnel ) , shift 2 ( 1 skilled + 1 unskilled personnel ) , shift 3 ( 1 skilled + 1 unskilled personnel ) ...

Kolkata Municipal Corporation - West Bengal

25989294 contractual arrangement for attending any type of fault along with routine upkeeping of h . t and l . t electrical network at behala fc dps and jinjira bazar mps under bdps . , arrangement for attending any type of fault / breakdown along with routine upkeep of h . t and l . t electrical network round the clock basis by providing skilled personnel like electrician , helper etc . including minor repairing of electrical equipments like motors , h . t switchgear , control panel , starter etc . along with lighting system as per direction of engr . in charge ....

Kolkata Municipal Corporation - West Bengal

25910819 operation by contract of hatisur drainage pumping station , daily wages per day for skilled personnel ( operator ) including esi 3 . 25% , epf 12% , eldi 0 . 50% , admn . charges 0 . 5% , national holidays 0 . 96% & agency charge 10% . ( 6 nos . / day x 730 days = 4380 mandays ) , wages per casual leaves for skilled ( operator ) . ( 6 nos . x 28 days for 2 years = 168 mandays ) ...

Kolkata Municipal Corporation - West Bengal

25204734 kmc / s_d / dlps / h / opr / 03 / 20 21 operation by contract of hatisur drainage pumping station . , daily wages per day for skilled personnel ( operator ) including esi 3 . 25% , epf 12% , eldi 0 . 50% , admn . charges 0 . 5% , national holidays 0 . 96% & agency charge 10% . ( 6 nos . / day x 730 days = 4380 mandays ) , wages per casual leaves for skilled ( operator ) . ( 6 nos . x 28 days for 2 years = 168 mandays ) ...